The very high throughput signal B field (VHT-SIG-B) is used for multiuser
scenario to set up the data rate and to fine-tune MIMO reception. It is modulated using MCS
0 and is transmitted in a single OFDM symbol.
The VHT-SIG-B field consists of a single OFDM symbol located
between the VHT-LTF and the data portion of the VHT format PPDU.
The very high throughput signal B (VHT-SIG-B) field contains the actual rate and A-MPDU length
value per user. For a detailed description of the VHT-SIG-B field, see section 21.3.8.3.6 of
IEEE® Std 802.11™-2016. The number of bits in the VHT-SIG-B field varies with the channel
bandwidth and the assignment depends on whether single user or multiuser scenario in
allocated. For single user configurations, the same information is available in the L-SIG
field but the VHT-SIG-B field is included for continuity purposes.
Field | VHT MU PPDU
Allocation (bits) | VHT SU PPDU
Allocation (bits) | Description |
---|
| 20 MHz | 40 MHz | 80 MHz, 160 MHz | 20 MHz | 40 MHz | 80 MHz, 160 MHz | |
---|
VHT-SIG-B | B0-15 (16) | B0-16 (17) | B0-18 (19) | B0-16 (17) | B0-18 (19) | B0-20 (21) | A variable-length field that indicates the size of the data
payload in four-byte units. The length of the field depends on the
channel bandwidth. |
VHT-MCS | B16-19 (4) | B17-20 (4) | B19-22 (4) | N/A | N/A | N/A | A four-bit field that is included for multiuser scenarios
only. |
Reserved | N/A | N/A | N/A | B17–19 (3) | B19-20 (2) | B21-22 (2) | All ones |
Tail | B20-25 (6) | B21-26 (6) | B23-28 (6) | B20-25 (6) | B21-26 (6) | B23-28 (6) | Six zero-bits used to terminate the convolutional
code. |
Total # bits | 26 | 27 | 29 | 26 | 27 | 29 | |
Bit field
repetition | 1 | 2 | 4 For 160 MHz, the 80 MHz channel is
repeated twice. | 1 | 2 | 4 For 160 MHz, the 80 MHz channel is
repeated twice. | |
For a null data packet (NDP), the VHT-SIG-B bits are set according to Table 21-15 of
IEEE Std 802.11-2016.