Model shunt inductor
RF Blockset / Equivalent Baseband / Series / Shunt RLC
The Shunt L block models the shunt inductor described in the block dialog box, in terms of its frequency-dependent S-parameters
The shunt L object is a two-port network, as shown in the following circuit diagram.
Inductance (H)
— Inductance of the shunt element1e-9
(default) | scalarScalar value for the inductance. The value must be non-negative.
Source of frequency data
— Frequency data sourceUser-specified
(default)When Source of frequency data is
User-specified
, specify as a vector of
frequencies in the Frequency data parameter.
Frequency data
— Frequency data range[1e9:1e6:3e9]
(default) | vectorFrequency data range, specified as a vector in hertz.
To set this parameter, first select
User-specified
in Source of
amplifier gain. This selection activates the
Visualization Tab which contains
Source of frequency data
Reference impedance (ohms)
— Reference impedance50
(default) | scalar Reference impedance of the coaxial transmission line, specified as a scalar in ohms.
Plot type
— Type of data plotX-Y plane
(default) | Composite data
| Polar plane
| Z Smith chart
| Y Smith chart
| ZY Smith chart
Type of data plot that you want to produce with your data specified as :
X-Y plane
— Generate a
Cartesian plot of your data versus frequency. To create linear,
semi-log, or log-log plots, set the Y scale
and X scale accordingly.
Composite data
—The composite
data plot automatically generates four separate plots in one
figure window, showing the frequency dependence of several
parameters.
Polar plane
— Generate a
polar plot of your data. The block plots only the range of data
corresponding to the specified frequencies.
Z Smith chart
, Y Smith
chart
, and ZY Smith
chart
— Generate a Smith® chart of your data. The
block plots only the range of data corresponding to the
specified frequencies.
Y Parameter1
— Type of parameters to plotS21
(default) | S11
| S12
| S22
| GroupDelay
| GammaIn
| GammaOut
| VSWRIn
| VSWROut
| OIP3
| IIP3
| NF
| NFactor
| NTemp
| TF1
| TF2
| TF3
| Gt
| Ga
| Gp
| Gmag
| Gmsg
| GammaMS
| GammaML
| K
| Delta
| Mu
| MuPrime
Type of parameters to plot, specified as one of the following
S11
, S12
,
S21
, S22
,
GroupDelay
, GammaIn
,
GammaOut
, VSWRIn
,
VSWROut
, OIP3
,
IIP3
, TF1
,
TF2
, TF3
,
Gt
, Ga
, Gp
,
Gmag
, Gmsg
,
GammaMS
, GammaML
,
K
, Delta
,
Mu
or MuPrime
. When noise is
spectral NF
, NFactor
and
NTemp
plotting is possible.
Y Parameter2
— Type of parameters to plotS11
(default) | S12
| S21
| S22
| GroupDelay
| GammaIn
| GammaOut
| VSWRIn
| VSWROut
| OIP3
| IIP3
| NF
| NFactor
| NTemp
| TF1
| TF2
| TF3
| Gt
| Ga
| Gp
| Gmag
| Gmsg
| GammaMS
| GammaML
| K
| Delta
| Mu
| MuPrime
Type of parameters to plot, specified as one of the following
S11
, S12
,
S21
, S22
,
GroupDelay
, GammaIn
,
GammaOut
, VSWRIn
,
VSWROut
, OIP3
,
IIP3
, TF1
,
TF2
, TF3
,
Gt
, Ga
, Gp
,
Gmag
, Gmsg
,
GammaMS
, GammaML
,
K
, Delta
,
Mu
or MuPrime
. When noise is
spectral NF
, NFactor
and
NTemp
plotting is possible.
Y Format1
— Plot formatAngle (degrees)
(default) | dB
| Magnitude (decibels)
| Abs
| Mag
| Magnitude (linear)
| Angle
| Angle (radians)
| Real
| Imag
| Imaginary
Plot format, specified as one of the following Magnitude
(decibels)
, Angle (degrees)
,
Real
, or Imaginary
.
Y Format2
— Plot formatdB
(default) | Magnitude (decibels)
| Abs
| Mag
| Magnitude (linear)
| Angle
| Angle (degrees)
| Angle (radians)
| Real
| Imag
| Imaginary
Plot format, specified as one of the following Magnitude
(decibels)
, Angle(degrees)
,
Real
, or Imaginary
.
X parameter
— X parameterFreq
(default)Parameter, specified as Freq
. This parameter
determines the data for x-axes on the X-Y plane plot.
X format
— Plot formatHz
(default) | Auto
| KHz
| MHz
| GHz
| THz
Plot format, specified as one of the following Hz
,
Auto
, KHz
,
MHz
, GHz
or
THz
.
Y scale
— Y-axis scaleLinear
(default) | Log
Y-axis scale, specified as Linear
or
Log
.
X scale
— X-axis scaleLinear
(default) | Log
X-axis scale, specified as Linear
or
Log
.
Plot
— Plot specified dataPlot the specified data using the plot button.
General Passive Network | LC Bandpass Pi | LC Bandpass Tee | LC Bandstop Pi | LC Bandstop Tee | LC Highpass Pi | LC Highpass Tee | LC Lowpass Pi | LC Lowpass Tee | Series C | Series L | Series R | Series RLC | Shunt C | Shunt R | Shunt RLC