Shunt C

Model shunt capacitor

  • Library:
  • RF Blockset / Equivalent Baseband / Series / Shunt RLC

  • Shunt C block

Description

The Shunt C block models the series inductor described in the block dialog box, in terms of its frequency-dependent S-parameters

The shunt C object is a two-port network, as shown in the following circuit diagram.

Parameters

expand all

Main

Scalar value for the capacitance. The value must be non-negative.

Visualization

When Source of frequency data is User-specified, specify as a vector of frequencies in the Frequency data parameter.

Frequency data range, specified as a vector in hertz.

Dependencies

To set this parameter, first select User-specified in Source of amplifier gain. This selection activates the Visualization Tab which contains Source of frequency data

Reference impedance of the coaxial transmission line, specified as a scalar in ohms.

Type of data plot that you want to produce with your data specified as :

  • X-Y plane — Generate a Cartesian plot of your data versus frequency. To create linear, semi-log, or log-log plots, set the Y scale and X scale accordingly.

  • Composite data—The composite data plot automatically generates four separate plots in one figure window, showing the frequency dependence of several parameters.

  • Polar plane — Generate a polar plot of your data. The block plots only the range of data corresponding to the specified frequencies.

  • Z Smith chart, Y Smith chart, and ZY Smith chart — Generate a Smith® chart of your data. The block plots only the range of data corresponding to the specified frequencies.

Type of parameters to plot, specified as one of the following S11, S12, S21, S22, GroupDelay, GammaIn, GammaOut, VSWRIn, VSWROut, OIP3, IIP3, TF1, TF2, TF3, Gt, Ga, Gp, Gmag, Gmsg, GammaMS, GammaML, K, Delta, Mu or MuPrime. When noise is spectral NF, NFactor and NTemp plotting is possible.

Type of parameters to plot, specified as one of the following S11, S12, S21, S22, GroupDelay, GammaIn, GammaOut, VSWRIn, VSWROut, OIP3, IIP3, TF1, TF2, TF3, Gt, Ga, Gp, Gmag, Gmsg, GammaMS, GammaML, K, Delta, Mu or MuPrime. When noise is spectral NF, NFactor and NTemp plotting is possible.

Plot format, specified as one of the following Magnitude (decibels), Angle (degrees), Real, or Imaginary.

Plot format, specified as one of the following Magnitude (decibels), Angle(degrees), Real, or Imaginary.

Parameter, specified as Freq. This parameter determines the data for x-axes on the X-Y plane plot.

Plot format, specified as one of the following Hz, Auto, KHz, MHz, GHz or THz.

Y-axis scale, specified as Linear or Log.

X-axis scale, specified as Linear or Log.

Plot the specified data using the plot button.

Introduced before R2006a