simOptions

Option set for sim

Description

example

opt = simOptions creates the default option set for sim.

example

opt = simOptions(Name,Value) creates an option set with the options specified by one or more Name,Value pair arguments.

Examples

collapse all

opt = simOptions;

Create an option set for sim specifying the following options.

  • Zero initial conditions

  • Input offset of 5 for the second input of a two-input model

opt = simOptions('InitialCondition','z','InputOffset',[0; 5]);

Create noise data for a simulation with 500 input data samples and two outputs.

noiseData = randn(500,2);

Create a default option set.

opt = simOptions;

Modify the option set to add the noise data.

opt.AddNoise = true;
opt.NoiseData = noiseData;

Use historical input-output data as a proxy for initial conditions when simulating your model.

Load a two-input, one-output data set.

load iddata7 z7

Identify a fifth-order state-space model using the data.

sys = n4sid(z7, 5);

Split the data set into two parts.

zA = z7(1:15);
zB = z7(16:end);

Simulate the model using the input signal in zB.

uSim = zB;

Simulation requires initial conditions. The signal values in zA are the historical data, that is, they are the input and output values for the time immediately preceding data in zB. Use zA as a proxy for the required initial conditions.

IO = struct('Input',zA.InputData,'Output',zA.OutputData);
opt = simOptions('InitialCondition',IO);

Simulate the model.

ysim = sim(sys,uSim,opt);

To understand how the past data is mapped to the initial states of the model, see Understand Use of Historical Data for Model Simulation.

Input Arguments

collapse all

Name-Value Pair Arguments

Specify optional comma-separated pairs of Name,Value arguments. Name is the argument name and Value is the corresponding value. Name must appear inside quotes. You can specify several name and value pair arguments in any order as Name1,Value1,...,NameN,ValueN.

Example: 'AddNoise',true','InputOffset',[5;0] adds default Gaussian white noise to the response model and specifies an input offset of 5 for the first of two model inputs.

Simulation initial conditions, specified as one of the following:

  • 'z' — Zero initial conditions.

  • Numerical column vector of initial states with length equal to the model order.

    For multi-experiment data, specify a matrix with Ne columns, where Ne is the number of experiments, to configure the initial conditions separately for each experiment. Otherwise, use a column vector to specify the same initial conditions for all experiments.

    Use this option for state-space models (idss and idgrey) only.

  • Structure with the following fields, which contain the historical input and output values for a time interval immediately before the start time of the data used in the simulation:

    FieldDescription
    InputInput history, specified as a matrix with Nu columns, where Nu is the number of input channels. For time-series models, use []. The number of rows must be greater than or equal to the model order.
    OutputOutput history, specified as a matrix with Ny columns, where Ny is the number of output channels. The number of rows must be greater than or equal to the model order.

    For an example, see Use Historical Data to Specify Initial Conditions for Model Simulation.

    For multi-experiment data, configure the initial conditions separately for each experiment by specifying InitialCondition as a structure array with Ne elements. To specify the same initial conditions for all experiments, use a single structure.

    The software uses data2state to map the historical data to states. If your model is not idss, idgrey, idnlgrey, or idnlarx, the software first converts the model to its state-space representation and then maps the data to states. If conversion of your model to idss is not possible, the estimated states are returned empty.

  • 'model' — Use this option for idnlgrey models only. The software sets the initial states to the values specified in the sys.InitialStates property of the model sys.

  • [] — Corresponds to zero initial conditions for all models except idnlgrey. For idnlgrey models, the software treats [] as 'model' and specifies the initial states as sys.InitialStates.

Covariance of initial states vector, specified as one of the following:

  • Positive definite matrix of size Nx-by-Nx, where Nx is the model order.

    For multi-experiment data, specify as an Nx-by-Nx-by-Ne matrix, where Ne is the number of experiments.

  • [] — No uncertainty in the initial states.

Use this option only for state-space models (idss and idgrey) when 'InitialCondition' is specified as a column vector. Use this option to account for initial condition uncertainty when computing the standard deviation of the simulated response of a model.

Input signal offset, specified as a column vector of length Nu. Use [] if there are no input offsets. Each element of InputOffset is subtracted from the corresponding input data before the input is used to simulate the model.

For multiexperiment data, specify InputOffset as:

  • An Nu-by-Ne matrix to set offsets separately for each experiment.

  • A column vector of length Nu to apply the same offset for all experiments.

Output signal offset, specified as a column vector of length Ny. Use [] if there are no output offsets. Each element of OutputOffset is added to the corresponding simulated output response of the model.

For multiexperiment data, specify OutputOffset as:

  • An Ny-by-Ne matrix to set offsets separately for each experiment.

  • A column vector of length Ny to apply the same offset for all experiments.

Noise addition toggle, specified as a logical value indicating whether to add noise to the response model.

Noise signal data specified as one of the following:

  • [] — Default Gaussian white noise.

  • Matrix with Ns rows and Ny columns, where Ns is the number of input data samples, and Ny is the number of outputs. Each matrix entry is scaled according to NoiseVariance property of the simulated model and added to the corresponding output data point. To set NoiseData at a level that is consistent with the model, use white noise with zero mean and a unit covariance matrix.

  • Cell array of Ne matrices, where Ne is the number of experiments for multiexperiment data. Use a cell array to set the NoiseData separately for each experiment, otherwise set the same noise signal for all experiments using a matrix.

NoiseData is the noise signal, e(t), for the model

y(t)=Gu(t)+He(t).

Here,G is the transfer function from the input, u(t), to the output, y(t), and H is the noise transfer function.

NoiseData is used for simulation only when AddNoise is true.

Output Arguments

collapse all

Option set for sim command, returned as a simOptions option set.

See Also

Introduced in R2012a