Slider

Tune parameter value with sliding scale

  • Library:
  • Simulink / Dashboard

  • Slider block

Description

The Slider block tunes the value of the connected block parameter during simulation. For example, you can connect the Slider block to a Gain block in your model and adjust its value during simulation. You can modify the range of the Slider block's scale to fit your data. Use the Slider block with other Dashboard blocks to create an interactive dashboard to control your model.

Connect Dashboard Blocks

Dashboard blocks do not use ports to connect to model elements. To connect dashboard blocks to variables and block parameters, use connect mode. Connect mode facilitates the process of connecting dashboard blocks in your model, especially when you want to connect multiple blocks at once. To connect a single dashboard block, you can also use the Connection table in the block dialog box.

Tip

You can modify dashboard block connections in your model during normal and accelerator mode simulations.

Note

Dashboard blocks cannot connect to variables until you update the model diagram. To connect dashboard blocks to variables or modify variable values between opening your model and running a simulation, update the model diagram using Ctrl+D.

To enter connect mode, select the block. Then on the block tab, click Connect. In connect mode, when you select one or more signals or blocks, a list of parameters and variables available for connection appears. Select a variable or parameter from the list to connect to the selected dashboard block. To connect another dashboard block, pause on another dashboard block and click the Connect button above it. Then, make a selection of signals and blocks in your model and choose a model element to connect.

When you finish connecting the dashboard blocks in your model, on the block tab, click Done Connecting.

Tip

You can hide the message shown on unconnected blocks using the set_param function with the ShowInitialText block parameter. The message also disappears when you connect the block.

Parameter Logging

Tunable parameters connected to dashboard blocks are logged to the Simulation Data Inspector, where you can view the parameter values along with logged signal data. You can access logged parameter data in the MATLAB® workspace by exporting the parameter data from the Simulation Data Inspector by using the UI or the Simulink.sdi.exportRun function. For more information about exporting data using the Simulation Data Inspector UI, see Export Data from the Simulation Data Inspector. The parameter data is stored in a Simulink.SimulationData.Parameter object, accessible as an element in the exported Simulink.SimulationData.Dataset.

Limitations

  • Except for the Dashboard Scope block and the Display block, dashboard blocks can only connect to real scalar signals.

  • The toolstrip does not support blocks that are inside a panel.

  • You cannot use the Connection table in the block dialog to connect a dashboard block to a block that is commented out. When you connect a dashboard block to a commented block using connect mode, the dashboard block does not display the connected value until the you uncomment the block.

  • Dashboard blocks cannot connect to model elements inside referenced models.

  • When you simulate a model hierarchy, dashboard blocks inside referenced models do not update.

  • Dashboard blocks do not support rapid accelerator simulation.

  • When you specify a block parameter value by indexing a variable array, the parameter does not appear in the Connection table. For example, a block parameter defined as engine(1) using the variable engine does not appear in the table.

    To access the parameter in the Connection table, assign the indexed value to a scalar variable, such as engine_1. Then, use the scalar variable to define the block parameter.

  • When you connect a dashboard block to a variable or parameter during simulation, the data for that variable or parameter is not logged to the Simulation Data Inspector. To log variable and parameter data to the Simulation Data Inspector, connect the dashboard block to the variable or parameter prior to simulation.

  • When you simulate a model in external mode with the Default parameter behavior set to Inlined, dashboard blocks can appear to change parameter and variable values. However, the change does not propagate to the simulation. For example, Gain blocks display changes made to the Gain parameter using the dashboard blocks, but the Gain value used in the simulation does not change.

Parameters

expand all

Select the variable or block parameter to control using the Connection table. To connect the block to a signal:

  1. Make a selection in the model that includes one or more blocks.

  2. Select the variable or parameter you want to connect.

  3. Click Apply.

To facilitate understanding and debugging your model, you can connect Dashboard blocks to variables and parameters in your model during simulation.

Note

To see workspace variables in the connection table, update the model diagram using Ctrl+D.

Programmatic Use

To programmatically connect a dashboard block to a tunable parameter or a variable, use a Simulink.HMI.ParamSourceInfo object. The Simulink.HMI.ParamSourceInfo object contains four properties. Some of the properties apply to connecting dashboard blocks to parameters, and some apply to connecting dashboard blocks to variables. Not all fields have a value for a connection because a given dashboard block connects to either a parameter or a variable.

Block Parameter: Binding
Type: Simulink.HMI.ParamSourceInfo
Default: []

Type of scale displayed on the block. Linear specifies a linear scale, and Log specifies a logarithmic scale.

Programmatic Use

Block Parameter: ScaleType
Type: string or character vector
Values: 'Linear' | 'Log'
Default: 'Linear'

Finite, real, double, scalar value specifying the minimum tick mark value for the scale. The minimum must be less than the value of the Maximum parameter.

Programmatic Use

To programmatically set the Minimum parameter, use a 1-by-3 vector containing values for the Minimum, Tick Interval, and Maximum parameters, in that order. To use the auto value for the Tick Interval, leave the Tick Interval position in the vector empty or specify -1.

Block Parameter: Limits
Type: 1x3 vector
Default: [0 -1 100]

Finite, real, double, scalar value specifying the maximum tick mark value for the scale. The maximum must be greater than the value of the Minimum parameter.

Programmatic Use

To programmatically set the Maximum parameter, use a 1-by-3 vector containing values for the Minimum, Tick Interval, and Maximum parameters, in that order. To use the auto value for the Tick Interval, leave the Tick Interval position in the vector empty or specify -1.

Block Parameter: Limits
Type: 1x3 vector
Default: [0 -1 100]

Finite, real, positive, whole, scalar value specifying the interval of major tick marks on the scale. When set to auto, the block automatically adjusts the tick interval based on the values of the Maximum and Minimum parameters.

Programmatic Use

To programmatically set the Tick Interval parameter, use a 1-by-3 vector containing values for the Minimum, Tick Interval, and Maximum parameters, in that order. To use the auto value for the Tick Interval, leave the Tick Interval position in the vector empty or specify -1.

Block Parameter: Limits
Type: 1x3 vector
Default: [0 -1 100]

Position of the block label. When the block is connected to an element in the model, the label is the name of the connected element.

Programmatic Use

Block Parameter: LabelPosition
Type: character vector
Values: 'Top' | 'Bottom' | 'Hide'
Default: 'Top'

Block Characteristics

Data Types

double | half | integer | single

Direct Feedthrough

no

Multidimensional Signals

no

Variable-Size Signals

no

Zero-Crossing Detection

no

Extended Capabilities

Introduced in R2015b