Select the diagnostic action to take if this model contains S-functions that do not specify whether they preclude this model from inheriting their sample times from a parent model.
Category: Diagnostics
Default: warning
none
Simulink® software takes no action.
warning
Simulink software displays a warning.
error
Simulink software terminates the simulation and displays an error message.
Not specifying an inheritance rule may lead to incorrect simulation results.
Simulink software checks for this condition only if the solver used to simulate this model is a fixed-step discrete solver and the periodic sample time constraint for the solver is set to ensure sample time independence
For more information, see Periodic sample time constraint.
Parameter: UnknownTsInhSupMsg |
Value: 'none' | 'warning' | 'error' |
Default: 'warning' |
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | error |