Initial state

Description

Loads the model initial states from a workspace before simulation begins.

Category: Data Import/Export

Settings

Default: Off, xInitial

On

Simulink® software loads initial states from a workspace.

Specify the name of a variable that contains the initial state values, for example, a variable containing states saved from a previous simulation.

Use the structure or structure-with-time option to specify initial states if you want to accomplish any of the following:

  • Associate initial state values directly with the full path name to the states. This eliminates errors that could occur if Simulink software reorders the states, but the initial state array is not correspondingly reordered.

  • Assign a different data type to each state's initial value.

  • Initialize only a subset of the states.

  • Initialize the states of a top model and the models that it references

See Load State Information for more information.

The Initial state parameter does not load initial state data from a data dictionary. When a model uses a data dictionary and you disable model access to the base workspace, the Initial State parameter still has access to resolve variables in the base workspace.

Off

Simulink software does not load initial states from a workspace.

Tips

  • The initial values that the workspace variable specifies override the initial values that the model specifies (the values that the initial condition parameters of those blocks in the model that have states specify).

  • Selecting the Initial state check box does not result in Simulink initializing discrete states in referenced models.

  • Avoid using an array for an initial state. If the order of the elements in the array does not match the order in which blocks initialize, the simulation can produce unexpected results. To promote deterministic simulation results, use the InitInArrayFormatMsg diagnostic default setting of warning or set the diagnostic to error.

    Instead of array format for the initial state, consider using a Simulink.SimulationData.Dataset object, structure, structure with time, or an operating point.

  • If you use a format other than Dataset, you can convert the logged data to Dataset format. Converting the data to Dataset makes it easier to postprocess with other logged data. For more information, see Dataset Conversion for Logged Data.

  • If you use Dataset format, you can specify the discrete state bus type by setting the state label to DSTATE_NVBUS (nonvirtual bus) or DSTATE_VBUS (virtual bus).

Command-Line Information

Parameter: LoadInitialState
Value: 'on' | 'off'
Default: 'off'
Parameter: InitialState
Type: variable (character vector) or vector
Value: any valid value
Default: 'xInitial'

Recommended Settings

ApplicationSetting
DebuggingNo impact
TraceabilityNo impact
EfficiencyNo recommendation
Safety precautionNo recommendation