Compute three-phase active and reactive powers using three-phase voltage and current phasors
Simscape / Electrical / Specialized Power Systems / Control & Measurements / Measurements
Simscape / Electrical / Specialized Power Systems / Fundamental Blocks / Measurements / Additional Measurements
The Power (3ph, Phasor) block outputs total active power P and reactive power Q of a three-phase voltage-current phasor signal pair. P and Q are computed as follows:
Ia*, Ib*, Ic* are the complex conjugates of Ia, Ib, and Ic.
The figure shows sign conventions:
Vabc
The three-phase phasor (three complex signals) voltage signal, in volts peak.
Iabc
The three-phase phasor (three complex signals) current signal, in amperes peak.
P
Returns the total active power, in watts.
Q
Returns the total active power, in vars.
Direct Feedthrough | Yes |
Dimensionalized | No |
The power_PhasorPowerMeasurements
example
shows the use of the Power (3ph, Phasor) block.