Magnetic reluctance
Magnetic Elements
The Reluctance block models a magnetic reluctance, that is, a component that resists flux flow. The ratio of the magnetomotive force (mmf) across the component to the resulting flux that flows through the component is constant, and the ratio value is defined as the reluctance. Reluctance depends on the geometry of the section being modeled.
The block is based on the following equations:
where
MMF | Magnetomotive force (mmf) across the component |
Φ | Flux through the component |
Reluctance | |
g | Thickness of the section being modeled, or length of air gap |
μ0 | Permeability constant |
μr | Relative permeability of the material |
A | Cross-sectional area of the section being modeled |
Connections N and S are magnetic conserving ports. The mmf across the reluctance is given by , and the sign of the flux is positive when flowing through the device from N to S.
To set the priority and initial target values for the block variables prior to simulation, use the Variables tab in the block dialog box (or the Variables section in the block Property Inspector). For more information, see Set Priority and Initial Target for Block Variables.
Thickness of the section being modeled, or length of air gap.
The default value is 0.001
m.
Area of the section being modeled. The default value is 0.01
m^2.
Relative permeability of the section material. The default value
is 1
.
The block has the following ports:
N
Magnetic conserving port associated with the block North terminal.
S
Magnetic conserving port associated with the block South terminal.