Return past value of operand
delay(u,tau)
delay(u,tau, History = u0, MaximumDelay = taumax)
Use the delay
operator in the equations
section
to refer to past values of expressions:
delay(u,tau)
= u(t-tau)
The full syntax is:
delay(u,tau, History = u0, MaximumDelay = taumax)
The required operands are:
u
— The first operand is
the Simscape™ expression being delayed. It can be any numerical
expression that does not itself include delay
or der
operators.
tau
— The second operand
is the delay time. It must be a numerical expression with the unit
of time. The value of tau
can change, but it must
remain strictly positive throughout the simulation.
The optional operands may appear in any order. They are:
History
— The return value
for the initial time interval (t
<= StartTime
+ tau
).
The units of u
and u0
must be
commensurate. The default u0
is 0.
MaximumDelay
— The maximum
delay time. taumax
must be a constant or parametric
expression with the unit of time. If you specify MaximumDelay
= taumax
, a runtime error will be issued whenever tau
becomes
greater than taumax
.
Note
You have to specify MaximumDelay
if the delay
time, tau
, is not a constant or parametric expression.
If tau
is a constant or parametric expression,
its value is used as the default for MaximumDelay
,
that is, taumax
= tau
.
At any time t
, delay(u,tau)
returns
a value approximating u
( t
- tau
)
for the current value of tau
. More specifically,
the expression delay(u,tau, History = u0)
is equivalent
to
if t <= (StartTime + tau) return u0(t) else return u(t-tau) end
In other words, during the initial time interval, from the start
of simulation and until the specified delay time, tau
,
has elapsed, the delay
operator returns u0
(or
0, if History
is not specified). For simulation
times greater than tau
, the delay
operator
returns the past value of expression, u
( t
- tau
).
Note
When simulating a model that contains blocks with delays, memory allocation for storing the data history is controlled by the Delay memory budget [kB] parameter in the Solver Configuration block. If this budget is exceeded, simulation errors out. You can adjust this parameter value based on your available memory resources.
For recommendation on how to linearize a model that contains blocks with delays, see Linearizing with Simulink Linearization Blocks.
This example shows implementation for a simple dynamic system:
The Simscape file looks as follows:
component MyDelaySystem parameters tau = {1.0,'s'}; end variables x = 1.0; end equations x.der == -delay( x,tau,History = 1.0 )*{ 1, '1/s' }; % x' = - x(t - 1) end end
MaximumDelay
is not required because tau
is
constant.
The { 1, '1/s' }
multiplication factor is
used to reconcile the units of expression and its time derivative.
See der
reference page for more
information.
For other examples of using the delay
operator, see source for the PS
Constant Delay and PS Variable Delay blocks in the Simscape Foundation library (open the block dialog box and click the Source
code link).
The Variable Transport Delay example