This example shows how to use and log local data stores. It also shows how to define, use and log global data stores to share global data among referenced models.
Open the example models. The top model sldemo_mdlref_dsm
references models sldemo_mdlref_dsm_bot
and sldemo_mdlref_dsm_bot2
. Logging of data stores is turned on for sldemo_mdlref_dsm
on the Data Import/Export pane of the Configuration Parameters dialog.
Reference model sldemo_mdlref_dsm_bot
amplifies the incoming signal by 5 if the signal is positive or by 2 if the signal is negative and writes the value of this signal to local data store RefSignalVal
. This local data store is configured to log all written values to the workspace after simulation. The logging parameters for this local data store are controlled by the Logging tab of the block parameters dialog.
Reference model sldemo_mdlref_dsm_bot2
sets the value of a global boolean data store named ErrorCond to true if the value of its incoming signal is outside of the range (-0.8, 0.8). The top model also monitors the data store ErrorCond and switches between the outputs of the two referenced models, depending on the value of that data store.
To specify to Simulink that the top model and both of the referenced models use the same memory for the Data Store named ErrorCond in each model, create an instance of a Simulink.Signal
object named ErrorCond in the base workspace. Since this object is visible to each model, its scope encompasses the individual models and implies that there is one global data store of that name that is shared among the models. Note that none of the three models contains a Data Store Memory block with a data store name of ErrorCond. If any model contained such a block, that block would define a data store local to the model, which would shadow the global data store.
Since the object ErrorCond defines a global data store, it must explicitly define the DataType
, Complexity
, Dimensions
, and SamplingMode
properties to non-inherited settings. SampleTime
and StorageClass
may be left as their inherited values, or explicitly set.
The example includes a MAT-file named sldemo_mdlref_dsm_data.mat
that contains the Simulink.Signal
object ErrorCond. The preload function of the model sldemo_mdlref_dsm
loads this MAT-file causing the object to be loaded in the base workspace. You can view this object by selecting the base workspace in the Model Explorer. You can also create this object from the MATLAB® command prompt. The following commands define the object used in this example:
ErrorCond = Simulink.Signal; ErrorCond.Description = 'Use to signal that subsystem output is invalid'; ErrorCond.DataType = 'boolean'; ErrorCond.Complexity = 'real'; ErrorCond.Dimensions = 1; ErrorCond.SamplingMode='Sample based'; ErrorCond.SampleTime = 0.1; ErrorCond.LoggingInfo.DataLogging = true;
To log all the values written to the global data store, set the DataLogging
property of the LoggingInfo
property of the Simulink.Signal
object. The LoggingInfo
property also allows specification of other logging parameters such as decimation and maximum points.
Simulink.LoggingInfo (handle) DataLogging: 1 NameMode: 0 LoggingName: '' DecimateData: 0 Decimation: 2 LimitDataPoints: 0 MaxPoints: 5000
Now you can simulate sldemo_mdlref_dsm
to see the output. The reference model sldemo_mdlref_dsm_bot
writes to the data store ErrorCond while the top model sldemo_mdlref_dsm
reads from the data store. The blue line represents the input to sldemo_mdlref_dsm_bot
; the green line represents the output of the Switch block. Note that the output switches when the magnitude of the input signal falls outside of the range.
Both the global data store ErrorCond and the local data store RefSignalVal are configured to log all written values after simulation. These logged results are stored in the base workspace in the dsmout
variable.
dsmout = Simulink.SimulationData.Dataset 'dsmout' with 2 elements Name BlockPath ____________ ________________________________________ 1 [1x1 DataStoreMemory] ErrorCond '' 2 [1x1 DataStoreMemory] RefSignalVal ...dlref_dsm/A|sldemo_mdlref_dsm_bot/DSM - Use braces { } to access, modify, or add elements using index.
To access the data stored for the local data store, use the getElement
function to get the correct data store element based on the name RefSignalVal.
>> dsmout.getElement('RefSignalVal')
Simulink.SimulationData.DataStoreMemory Package: Simulink.SimulationData Properties: Name: 'RefSignalVal' BlockPath: [1x1 Simulink.SimulationData.BlockPath] Scope: 'local' DSMWriterBlockPaths: [1x2 Simulink.SimulationData.BlockPath] DSMWriters: [101x1 uint32] Values: [1x1 timeseries]
Data is stored in a timeseries
within the Values
field.
>> plot(dsmout.getElement('RefSignalVal').Values);
To determine which block wrote to the data store at a given time, use the DSMWriters
property. This array contains a list of indices into the DSMWriterBlockPaths
array. For example, the block path of the Data Store Write block that wrote the 5th value to the data store can be obtained as follows:
>> dsm = dsmout.getElement('RefSignalVal'); >> dsm.DSMWriterBlockPaths(dsm.DSMWriters(5))
Simulink.SimulationData.BlockPath Package: Simulink.SimulationData Block Path: 'sldemo_mdlref_dsm/A' 'sldemo_mdlref_dsm_bot/PositiveSS/DSW' Use the getBlock method to access block path character vectors from this object.