Power spectral density estimate using modified covariance method
Estimation / Power Spectrum Estimation
dspspect3
The Modified Covariance Method block estimates the power spectral density (PSD) of the input using the modified covariance method. This method fits an autoregressive (AR) model to the signal. It does so by minimizing the forward and backward prediction errors in the least squares sense. The Estimation order parameter value specifies the order of the all-pole model. To guarantee a valid output, the Estimation order parameter must be less than or equal to two thirds of the input vector length. The block computes the spectrum from the FFT of the estimated AR model parameters.
The input must be a column vector. This input represents a frame of consecutive time samples from a single-channel signal. The block outputs a column vector containing the estimate of the power spectral density of the signal at Nfft equally spaced frequency points. The frequency points are in the range [0,Fs), where Fs is the sampling frequency of the signal.
Selecting Inherit FFT length from estimation order, specifies that Nfft is one greater than the estimation order. Clearing the Inherit FFT length from estimation order parameter allows you to use the FFT length parameter to specify Nfft as a power of 2. The block zero-pads or wraps the input to Nfft before computing the FFT.
When you select the Inherit sample time from input check box, the block computes the frequency data from the sample period of the input signal. For the block to produce valid output, the following conditions must hold:
The input to the block is the original signal, with no samples added or deleted (by insertion of zeros, for example).
The sample period of the time-domain signal in the simulation equals the sample period of the original time series.
If these conditions do not hold, clear the Inherit sample time from input check box. You can then specify a sample time using the Sample time of original time series parameter.
See the Burg Method block reference for a comparison of the Burg Method, Covariance Method, Modified Covariance Method, and Yule-Walker Method blocks.
Specify the order of the AR model. To guarantee a valid output, the Estimation order parameter must be less than or equal to two thirds of the input vector length.
When you select this check box, the option specifies that the FFT length is one greater than the estimation order. To specify the number of points on which to perform the FFT, clear this check box. You can then specify a power of two FFT length using the FFT length parameter.
Enter the number of data points, Nfft, on which to perform the FFT. When Nfft is larger than the input frame size, the block zero-pads each frame as needed. When Nfft is smaller than the input frame size, the block wraps each frame as needed. This parameter becomes visible only when you clear the Inherit FFT length from estimation order check box.
If you select the Inherit sample time from input check box, the block computes the frequency data from the sample period of the input signal. For the block to produce valid output, the following conditions must hold:
The input to the block is the original signal, with no samples added or deleted (by insertion of zeros, for example).
The sample period of the time-domain signal in the simulation equals the sample period of the original time series.
If these conditions do not hold, clear the Inherit sample time from input check box. You can then specify a sample time using the Sample time of original time series parameter.
Specify the sample time of the original time-domain signal. This parameter becomes visible only when you clear the Inherit sample time from input check box.
Kay, S. M. Modern Spectral Estimation: Theory and Application. Englewood Cliffs, NJ: Prentice-Hall, 1988.
Marple, S. L. Jr., Digital Spectral Analysis with Applications. Englewood Cliffs, NJ: Prentice-Hall, 1987.
Orfanidis, S. J. Introduction to Signal Processing. Englewood Cliffs, NJ: Prentice-Hall, 1995.
Port | Supported Data Types |
---|---|
Input |
|
Output |
|
The output data type is the same as the input data type.
Burg Method | DSP System Toolbox |
Covariance Method | DSP System Toolbox |
Modified Covariance AR Estimator | DSP System Toolbox |
Short-Time FFT | DSP System Toolbox |
Yule-Walker Method | DSP System Toolbox |